Gac. méd. Méx ; 158(6): 380-386, nov.-dic. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1430367

ABSTRACT

Resumen Introducción: Las bioprótesis de válvulas cardiacas son el estándar de oro para el reemplazo quirúrgico de la válvula aórtica en pacientes seleccionados. Objetivo: Evaluar la seguridad y eficacia de la válvula cardiaca bioprotésica del Instituto Nacional de Cardiología (INC) en humanos. Métodos: Estudio unicéntrico que incluyó 341 pacientes que se sometieron a reemplazo valvular quirúrgico único de válvula aórtica con válvula INC. Resultados: Se realizaron 318 implantes de novo (93 %) y 23 como segunda cirugía (7 %); las puntuaciones STS fueron de 1.4 y 1.8 % y el seguimiento de 42 y 46 meses, respectivamente. No existieron diferencias en las complicaciones ni en la tasa de implantación de marcapasos. Ambos grupos mantuvieron una FEVI normal. Se observó mejoría global en la clase funcional con empeoramiento solo en dos pacientes del grupo de novo. La disfunción de la prótesis INC que ameritó reintervención quirúrgica se observó en ocho pacientes (4.65 %) del grupo de novo versus un paciente (7.69 %) con segunda cirugía. Conclusiones: La válvula cardiaca INC es eficaz y segura, se asocia a baja tasa de complicaciones y mejoría de la clase funcional durante el seguimiento a largo plazo. Se necesitan estudios prospectivos comparativos de esta válvula.


Abstract Introduction: Heart valve bioprostheses are the gold standard for aortic valve surgical replacement in selected patients. Objective: To evaluate the safety and efficacy of the of the National Institute of Cardiology (INC) bioprosthetic heart alve of the National Institute of Cardiology (INC) bioprosthetic heart valve in humans. Methods: Single-center study that ncluded 341 patients who underwent single surgical aortic valve replacement with INC heart valve. Results: 318 implants were performed de novo (93%) and 23 as redo surgery (7%); STS scores were 1.4 and 1.8%, and follow-up was for 42 and 46 months, respectively. There were no differences in clinical complications or pacemaker implantation rate. Both groups maintained a normal LVEF. Overall improvement in functional class was observed, with worsening only in two patients of the de novo group. INC prosthesis dysfunction requiring surgical reintervention was observed in eight patients (4.65%) of the de novo group vs. one patient in the redo group. Conclusions: The INC heart valve is efficacious and safe, and is associated with a The INC heart valve is efficacious and safe, and is associated with a low rate of complications and functional class improvement during long-term follow-up. Prospective, comparative studies of this valve are required.

2.
Gac. méd. Méx ; 156(4): 276-282, Jul.-Aug. 2020. graf
Article in English | LILACS | ID: biblio-1249911

ABSTRACT

Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs’ antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Subject(s)
Animals , Male , Female , Rabbits , Paclitaxel/administration & dosage , Sirolimus/administration & dosage , Drug-Eluting Stents , Prosthesis Design , Spectrophotometry, Infrared , Swine , Follow-Up Studies , Disease Models, Animal , Microscopy